The Effects of a Flexibility Enhancement Program on Athletic
Performance
Brian-Matthew
Hickey, PhD
Florida State University
©
2000
(Abstract)
When
examining the critical factors that contribute to high level athletic
performance, flexibility is one of the key items. It has been hypothesized that
improving an athlete's flexibility may allow them to be more successful in their
chosen athletic endeavor. More specifically, speed, the most vital determinant
of athletic success, may be significantly improved by incorporating some form of
flexibility enhancement into an athlete's training program.
Recently, a
scientific study was conducted to examine whether or not including a specific
form of flexibility training in an athlete's daily training routine would
improve sprint performance. In this study, 30 men age 20-35, who exercised an
average of 7.5 hours per week during the six months prior to the study served as
subjects. Their preferred modes of training were free weights and cardiovascular
machines (Stairmaster, stationary bicycle etc.). Fifteen individuals included
twice daily, five minute flexibility sessions into their exercise routine,
thereby acting as the treatment group. The second group served as the control
and did not incorporate any additional flexibility training into their pre-
existing training program. Flexibility was assessed by a sit and reach test,
power through a vertical jump test and speed by a 40 meter dash. The results,
expressed as percent improvement from the pre test to the post test, are as
follows:
Percent
Improvement from Pre Test to Post Test
|
|
Flexibility
|
Power
|
Speed
|
|
Treatment group
|
64%
|
10%
|
5%
|
|
Control group
|
9%
|
0%
|
0%
|
These results indicate that
supplementing an athlete's daily training routine with flexibility training is a
promising way to increase athletic performance. In essence a cascade of events
is set into motion. Flexibility improves, which in turn positively affects power
generation, thereby augmenting speed.
In this study, the Intracell Stick was used
by the treatment group as the flexibility enhancing modality that was added to
their training program. The Intracell Stick is a 24 inch instrument, containing 14,
one inch free-moving spindles that rotate around a semi-flexible core. By
applying rolling pressure to muscles following a workout, blood flow is
increased. As a result, waste products from various metabolic processes are
removed, recovery is enhanced and soreness reduced. An additional benefit of
using The Intracell Stick is that it allows the user to locate and treat specific
tender areas in the musculature. This allows the user to give attention to both
the weakest and strongest regions of each muscle, promoting development of the
entire range of motion.
The
results of this study demonstrate that the Intracell Stick has the
potential to improve athletic performance through increasing muscle flexibility,
thereby improving power, speed and the ability to recover faster from intense
training.
THE
FLORIDA STATE UNIVERSITY
COLLEGE
OF EDUCATION
THE
EFFICACY OF THE ROM DEVICE
AS
AN ERGOGENIC AID
WITH
RESPECT TO SELECT MEASURES OF
POWER
GENERATION, FLEXIBILITY AND SPEED
BY
BRIAN
MATTHEW HICKEY
Fall,
2000
TABLE OF CONTENTS
LIST
OF
TABLES
...
.ix
LIST
OF
FIGURES
...x
ABSTRACT
.
xi
CHAPTER
1 INTRODUCTION
..
...
.1
Purpose
of the Study.
..
. . . .
. . . .
...
2
Research
Questions
..
..
.2
Significance
of the Study
...3
CHAPTER
2 REVIEW OF LITERATURE
.....
.....4
Power
in the Athletic
Arena
...
....4
Flexibility
Enhancing
Modalities
..
.6
Ballistic
Stretching
..
...9
Passive
Stretching
..
9
Static
Stretching
.
..10
Proprioceptive
Neuromuscular Facilitation
.
10
Active
Isolated Stretching
..
..11
Massage
..
..12
The
ROM Device: An Eclectic Modality
.
...13
The
Benefits of a Flexibility Enhancement Program
..
.15
Time
Course of Adaptation to Training Stimuli
..17
Periodization
Overview
...18
Time
Necessary for Adaptation
...19
Literature
Void
.
.20
Research
Hypotheses and Rationale
.
23
Research
Question 1
23
Research
Question 2
23
Research
Question 3
24
CHAPTER
3
METHOD
..25
Research
Design
.
...25
Participants
...27
Test
Battery
.
..27
Sit and Reach
Test
...28
40 meter Dash
Testing
.
29
Vertical Jump
Testing
..29
Intervention
Procedures
...30
Statistics
...30
CHAPTER
4 RESULTS
..32
Descriptive
Data
. .
...32
Data
Analysis by Hypothesis
...33
CHAPTER
5 DISCUSSION AND CONCLUSIONS
.
36
Research
Question 1: 40 Meter Dash Performance
.
36
Research
Question 2: Vertical Jump Performance
..38
Research
Question 3: Sit and Reach Performance
..39
General
Discussion
..41
Hemodynamic
Factors
.
42
Temperature
Dependant Effects
..44
Trigger
Points
..45
Delimitations
of the Study
...46
Future
Directions
.
47
Summary
and Conclusions
.
..49
APPENDIX
A Training Program Survey and Log
.
...
..50
APPENDIX
B Informed Consent Form
.
.
51
REFERENCES
55
BIOGRAPHICAL
SKETCH
...60
LIST OF TABLES
Table 1. Age of
Subjects in the Treatment and Control Groups
..33
Table 2. Hours
Trained Per Week for the Treatment and Control Groups
..
...33
Table 3. Test
Battery Results
...35
Table 4. Paired
Sample t-test Results
..35
LIST OF FIGURES
Figure 1. The
Effects of the ROM Device on 40 Meter Run Performance
...37
Figure 2. The
Effects of the ROM Device on Vertical Jump Performance
.
.38
Figure 3. The
Effects of the ROM Device on Sit and Reach Test Performance
...40
Figure 4. The
Ergogenic Cascade for the ROM Device
..
...
.41
CHAPTER
1
INTRODUCTION
Power is often the deciding factor in athletic performance.
This explosive strength becomes especially critical in anaerobic events.
Essential considerations in the generation of highly explosive power are
muscle structure and the rate at which muscles can generate force.
The velocity of contraction, with respect to maintaining a high degree of
force output, further moderates top anaerobic performance (Kraemer & Newton,
1994).
The
manifestation of power in the running gait is speed.
Sprinting speed is a function of biomechanical form, maintenance of
maximal velocity, improved acceleration to maximum velocity and an increase in
both stride length and stride frequency (Dintiman, Ward & Tellez 1997).
As
delineated by the five components of fitness, muscle flexibility is an integral
component of optimal human performance. Athletes
possessing a high degree of flexibility traditionally demonstrate an increased
proficiency in movements which are fundamental to athletic performance, and are
able to perform at the zenith of their potential without injury, when contrasted
with their less flexible counterparts (Bonci & Belcher, 1994).
Furthermore, the inflexible muscle is predisposed to injury (Wang,
Whitney, Burbett, & Janosky, 1993). Consequently,
athletes who exhibit reduced levels of flexibility are at risk for experiencing
the negative duality of reduced performance and increased risk of injury. With respect to ergogenic properties, stretching, a modality
for flexibility enhancement, prepares the muscle for vigorous activity (Liston,
1999).
A sure fire way to improve power generation, hence athletic performance,
is through the implementation of a flexibility enhancement program (Girouard
& Hurley, 1995). Hamstring
flexibility may be significantly improved in as little as three weeks via a
passive stretching program (Godges, MacRae, & Engle, 1993).
Daily employment of either static, dynamic or proprioceptive
neuromuscular facilitation stretching modalities has been shown to improve
flexibility and associated measures of localized muscular strength and endurance
in less than two months (Kokkonen & Lauritzen, 1995; Lucas & Koslow,
1984). Additionally, benefits from
the long run augmentation of flexibility include the prevention of sprains and
strains (Bonci & Belcher, 1994).
Purpose
of the Study
The purpose of this
study is to investigate the effects associated with the employment of a self
massage program using the ROM Device on anaerobic sprint performance, and field
tests of flexibility and power.
Research
Questions
In order to examine the efficacy
of employing the ROM Device as an ergogenic aid, with respect to flexibility,
power and speed, the following questions needed to be addressed:
1.
Does implementation of a self massage program utilizing the ROM Device
improve 40 meter dash performance?
2.
Does implementation of a self massage program utilizing the ROM Device
improve vertical jump performance?
3.
Does implementation of a self massage program utilizing the ROM Device
improve sit and reach test performance?
Significance of the Study
The results of this
study may impact anaerobic performance in a variety of ways. First and foremost,
an absolute improvement in 40 meter dash performance may indicate that regular
use of the ROM Device could improve linear, anaerobic sprinting performance.
Second, an absolute improvement in vertical jump may indicate that regular use
of the ROM Device could improve the development of lower limb muscular power.
Third, an absolute improvement in sit and reach score may indicate that regular
use of the ROM Device could improve hamstring and lower back flexibility.
Significant results from
this study may lend credence to the belief that improved flexibility is an
integral component in enhanced power, which in turn may positively affect
running speed. Furthermore, this
study may demonstrate that a commitment to a flexibility enhancement modality
could serve as an ergogenic aid with respect to anaerobic activities.
CHAPTER
2
REVIEW
OF LITERATURE
In providing a theoretical and practical basis for this study, this
review of literature will address four areas.
First, there will be an examination of the paradigm of power generation
as it applies to anaerobic athletic events.
Second, flexibility enhancing modalities which are currently accepted as
ergogenics within the context of the athletic arena will be discussed.
Third, the time course of adaptation to training stimuli will be
discussed. Last, the void in
current literature as it pertains to aforementioned topics will be scrutinized.
Power
in the Athletic Arena
In
short duration activities, the ability to develop force very rapidly is a key
determinant to success. However,
the ability to develop a high level of force is not as important as the ability
to develop a high level of force in a very small time frame.
The development of muscle mass and absolute strength are the foundation
of power generation, but in isolation possessing a high degree of these
qualities may actually hinder athletic performance (Staley, 2000). In light of the pre-existing limits of human physiology, the
sport sciences are challenged with the formidable task of continually unearthing
ways in which to shift the force - velocity curve to the left.
Such a transition will reduce the time frame necessary to generate
performance specific force. Hence, an increase in power will follow.
By improving an athlete's flexibility, it is intuitive that range of
motion will be improved. It is hypothesized that an increase in flexibility will lead
to an improvement in power and a resulting leftward shift of the force -
velocity curve (Gordon, Huxley & Julian, 1966).
Power
may be defined as the greatest possible neuromuscular impulse generated over a
given time period (Schmidtbleicher, 1992).
Maximal rate of force development, explosive strength, is the
neuromuscular system's ability to produce a contraction at very high velocities.
Power is further moderated by the initial rate of force development.
This construct can best be described as starting strength, or the amount
of power generated when a movement pattern is initiated.
As the interval of the force producing cycle decreases to a duration
below 250 ms per cycle, maximal rate of force development and initial rate of
force development are the main determinants of success.
The dominant factor in actions lasting in excess of 250 ms per cycle is
maximal strength (Schmidtbleicher, 1992).
Power
production in the running gait, or similar short duration cyclical activities,
is typified by a small angular displacement and a high degree of intermuscular
coordination. Generation of such
power is dependent upon the following mechanisms.
Prior to ground contact, the extensor muscles are activated in accordance
with the central motor program. Cross
bridge formation inhibits elasticity, thereby reducing muscle length at the
point of initial ground contact. Simultaneously,
a segmented stretch reflex ensues to augment muscular force development so that
elastic energy can be stored in the tendons of the main extensor muscles.
This process creates a powerful push off phase of the running gait.
A lower level of neural activation characterizes the concentric phase of
the running gait (Schmidtbleicher, 1992).
The
magnitude and quality of power generated is a function of the muscle's
innervation pattern and the functional strength of the muscle - tendon system
with respect to its contractile and elastic capacities.
Besides concentric and isometric contractions, power generation is
further moderated by the eccentric component of contraction (Schmidtbleicher,
1992). Consequently, when seeking
to design and implement a training program with increased sport specific power
generation as its specific goal, the three critical considerations are: (a) the
prevention of reflex inhibition, (b) an increase in neural activation, and (c)
the selection of modalities which will promote structural changes in muscle and
associated tissues in a minimal time frame (Hutton, 1992).
Flexibility
Enhancing Modalities
Flexibility, an essential quality of the muscular system, is critical for
athletic performance. A lack of
flexibility predisposes the athlete to injury, especially strains.
A complete range of motion is necessary for the successful execution of
athletic skills. When the muscle
exhibits a high capacity to move through a complete range of motion in a minimum
time frame, there is an increased protection against injury (Roy & Irvin,
1983).
When examined in the context of the athletic arena, the interaction of
the muscle - joint complex may be viewed as a physiologic torque generating
system. As specified by the muscle
architecture, assuming uniform moment arms, a joint capable of a larger range of
motion will produce greater torque than a joint with a more limited range of
motion (Hoy, Zajac and Gordon, 1990). The
negative correlation between speed of contraction and torque generation lies at
the crux of power development. Specifically, maximal athletic performance hinges on the
athlete's ability to produce an optimal contractile force relative to the rate
of change in the joint angle.
In general, the plasticity of the myogenic component plays a critical
role in determining muscular pliability (Noth, 1992).
Consequently, the more an individual participates in repetitive motion
activities, the greater the risk of developing tightness in the musculature that
generates these movements. As the
range of motion becomes increasingly constricted, the biomechanical efficiency
is compromised and injury risk escalates. In
order to prevent the onset of these negative qualities, flexibility needs to be
maintained or improved (Roy & Irvin, 1983).
The mobility of an articulation is defined as the amount of motion
experienced before being restricted by the surrounding tissues.
Mobility, dictated by the articulation's total range of motion, is
typically expressed in degrees of flexion and quantifies flexibility.
Since flexibility is specific to each joint, its range of motion is
influenced by the shape of the articulation, and the tightness of the bones and
ligaments that encapsulate the joint. Flexibility
exercises are designed to enhance the "stretchability" of the
ligaments and tendons. An enhanced
range of motion allows for a more flexible articulation to move safely into
positions which an inflexible one cannot achieve.
Consequently, flexibility is an important factor in the performance of
motor skills and the prevention of injuries (Kreighbaum & Barthels, 1985).
When
examining joint mobility, four factors create resistance to motion.
These constraints may be either neurogenic, myogenic, joint or frictional
in nature. With respect to joint
capacity being restrained neurogenically in a voluntary muscle, as neural
activation increases so does tonicity. As
a result, the muscle becomes resistive to stretch (Hutton, 1992).
At the myogenic level, thixotropic bonds between actin and myosin
filaments play a role in limiting flexibility.
Thixotropy, the viscosity of a gel, is altered with activity.
Consequently, when the muscle is exposed to a pre-stretch condition that
reduces the viscosity of the actin-myosin complex, range of motion about the
joint will increase (Hutton, 1992). The
limitations placed upon flexibility by joint architecture include: (a) bone
articulation and physical structure, (b) joint capsule composition, and (c)
ligament and tendon attachment (Hutton, 1992).
Frictional constraints are concerned with lubrication, contact area and
the coefficient of friction (Kreighbaum & Barthels, 1985).
These conditions are in turn linked to joint architecture, the supply of
synovial fluid, and thixotropic response (Hutton, 1992).
In
an acute setting only the neurogenic and myogenic constraints are subject to
voluntary control. In general,
emphasis has been placed on the neurogenic component via employing stretching
techniques that presumably enhance the level of inhibition to the muscle
experiencing treatment (Hutton, 1992). It
is theorized that reflex control is the predominant component of flexibility
enhancement (Sherrington, 1906). The
primary flexibility enhancement modalities are: (a) ballistic stretching, (b)
passive stretching, (c) static stretching, (d) proprioceptive neuromuscular
facilitation, (e) active isolated stretching, and (f) massage therapy (Chaitow,
1980; Hutton, 1992; Mattes, 1995).
Ballistic Stretching
A ballistic stretch may be
characterized by the application of a stretch torque through a movement which is
both dynamic and rapid. The extreme
limits of the range of motion are explored.
This modality has come under criticism since it has been shown to
aggravate the muscles and associated connective tissues.
Additionally, the production of small muscle tears and a resulting
generation of inflexible scar tissue may result. Last, a stretch reflex may be initiated, causing a rapid
contraction of the muscle. This
may, in turn lead to spasms and the creation of an over tight, rather than
relaxed, muscle (Chaitow, 1980; Hutton, 1992).
Passive Stretching
The
passive stretching modality is usually employed when an individual is paralyzed,
or when the agonist muscle group is injured.
In these instances it is crucial to maintain joint range of motion.
If the musculotendon unit is not activated on a regular basis, it will
permanently shorten and joint motion will be lost.
Passive stretching requires assistance from an individual who provides a
continuous resistance which is just below the pain threshold.
The duration of each stretch may last up to one minute.
It should be a slow steady force, that gently lengthens the isolated
muscle. This modality has several drawbacks. First, it is dependant on the assistant and their judgment.
Therefore, an error could easily reverse all benefits or initiate the
onset of a stretch reflex. Additionally, this type of stretching may be painful and
there is no motor learning or improvement in active range of motion.
It fails to activate or strengthen the weak, overstretched agonist
muscle. Consequently, there is no
enhancement of a coordinated movement pattern (Mattes, 1995).
Static
Stretching
The
static stretch has been used for centuries as a modality to increase range of
motion (Mattes, 1995). It is
characterized by placing a joint in the outer limits of its present range of
motion and then subjecting it to a stretch torque (Hutton, 1992).
This torque may be passively induced or enhanced through the application
of weights. A drawback to this
protocol is the potential for overstretch, a risk of damage to the muscle or its
associated tendons and the plausible initiation of a stretch reflex.
In some instances pre-workout stretching, employing a static based
protocol, may lead to a higher incidence of injury (Liston, 1999).
Proprioceptive
Neuromuscular Facilitation (PNF)
Kokkonen
and Lauritzen (1995) have demonstrated that Proprioceptive Neuromuscular
Facilitation is a viable modality for increasing localized muscular strength,
endurance and flexibility. Using a
repeated measure design with a control group, the following results were
reported. In the male experimental
group, flexibility increased 38%, strength 17.2% and localized muscular
endurance 35.6%. The female
experimental group exhibited the pursuant gains: a 23.2% increase in
flexibility, a 16.8% increase in strength, and a 35.5% increase in localized
muscular endurance. Furthermore,
the control group made no significant improvement during the intervention
period.
Proprioceptive
neuromuscular facilitation uses a maximal pre-contraction of the muscle group
about to undergo elongation (Hutton, 1992).
Its theoretical underpinnings may be linked to the theory of successive
induction, whereby the agonist is successively excited to induce less reflex
activity (Sherington, 1906). This
modality may be subdivided into: (a) contract relax, and (b) contract relax -
agonist contract. In a contract
relax stretch, the muscle is first maximally contracted then subject to a static
stretch. The contract relax -
agonist contract stretch also begins with a maximal contraction. At this point however, there is an accompanying contraction
of the agonist. In both modalities,
the stretch torque is usually enhanced by a second party. As with passive stretching, success or failure is linked to
the individual assisting in the process. Furthermore,
it is time consuming and dependant upon sustaining exertion while providing a
graded resistance to the movement (Mattes, 1995).
Active
Isolated Stretching (AIS)
Many
stretching modalities are characterized by an isometric, eccentric muscular
contraction. Active Isolated
Stretching (AIS) is rooted in the belief that these techniques, which work
muscles and connective tissue while they are actively contracting, makes the
reduction of muscle tension highly unlikely.
Additionally, soreness or injury may result.
Furthermore, AIS does not employ assistance from others since outside
forces may move joints too far. The
AIS method uses a contraction of the agonist muscle followed by a relaxation of
the antagonist. As with the other
modalities, AIS claims to enhance recovery, create soft pliable scar tissue
following injury, prevent and eliminate trigger points, reduce swelling, edema
and bruising, activate the lymphatic system, enhance lung ventilation, promote
the removal of toxins and acids, augment capillary growth, and nourish and
lubricate the musculature (Mattes, 1995). The
primary drawback to this modality is the time commitment.
In general, the program takes 30 minutes, excluding warm up.
Furthermore, AIS stretches last no longer than two seconds (Liston,
1999). To this end, this modality
appears to be a derivative of ballistic stretching, and when used
inappropriately, may actually damage the muscle.
Specifically, predisposition to injury is highest when a thorough warm up
does not precede the implementation of a flexibility enhancement protocol (Coe,
1996).
Massage
Massage,
as a therapeutic and flexibility enhancing modality, dates back to Hippocrates.
The underlying goal of massage therapy is to allow for body-mind
reintegration and balance via the creation of a therapeutic experience which
affords an individual the opportunity to release their physical and emotional
tensions (Long, 1996). The aim is
to remove the substances trapped in the muscles which are not dispelled by
exercise. By dispersing these
toxins, it is hoped that the signs and symptoms of fatigue are also eliminated.
The benefits of massage exist within the physical, physiological and
psychological realms. In general, massage seeks to reduce the perception of
localized muscular pain, mobilize and enhance ranges of motion, improve blood
and lymph circulation, sedate the nervous system and eliminate or prevent
trigger points. Additionally, chest
massage has been shown to enhance lung tidal volume (Wood & Becker, 1981).
Following a massage treatment, hemoglobin levels and red blood cell count
have been shown to improve (Schneider & Havens, 1915).
Massage tends to open sebaceous and sweat glands, thereby improving their
function (Krusen, 1941). Psychologically,
a massage treatment often results in soothing feeling characterized by reduced
stress levels (Wood & Becker, 1981). Two
primary drawbacks to massage therapy are time investment and monetary factors.
In order for this to be a viable therapeutic modality, treatment sessions
need to occur 2-3 times a week. Often
a massage session will last upwards of one hour, with fees typically starting at
$50 (Long, 1996).
The
ROM Device: An Eclectic Modality
For many years a
debate has raged over the foremost way to enhance flexibility.
Some claim that static stretching produces the best results, while others
argue for activated isolated stretching or proprioceptive neuromuscular
facilitation (Mattes, 1995). Still
other factions believe that massage is pre-eminent in terms of its benefits (Chaitow,
1980). Despite these polarized opinions, there is not one, clear
cut, optimal technique. Consequently,
in order to maximize the gains from a flexibility enhancement program, an
eclectic tact should be taken. The
key features of each method may be incorporated into a progressive system
designed to maximize gains within a minimum time frame.
Recently, the ROM (Range of Motion) Device has been developed as a tool
which allows the user to passively enhance their flexibility through the
implementation of a self massage technique (Bonci & Belcher, 1994).
The tool measures 24 inches in length.
It contains 14 one inch free moving spindles which rotate independently
around a semi rigid plastic core. Ease
of use is enhanced by handles on either end (Bonci & Belcher, 1994). By applying deep rolling pressure to the muscles a stripping
massage is facilitated. The effect
of this procedure is to relieve intramuscular pressure and increase localized
blood flow (Bonci & Belcher, 1994).
The basic premise of how the ROM Device enhances flexibility is as
follows. An inactive muscle is
characterized by a low degree of pliability.
Additionally, during inactivity, metabolic wastes tend to become trapped
in the muscle, further reducing fluidity. A
sudden loading of a cool muscle may cause extensive stretching of the muscle
fibers. This overstretch tends to
place an adverse strain on the localized muscular system, thereby negatively
impacting musculoskeletal flexibility and providing an ideal medium for the
formation of trigger points. Implementation of a self massage program utilizing the ROM
Device has shown a propensity to dilate blood vessels. Consequently, trapped metabolites are removed, circulation is
increased and the muscle is prepared for loading (Bonci & Belcher, 1994).
Preliminary anecdotal results show that the ROM Device has a profound
effect on muscle flexibility, strength, endurance and recovery from intense
exercise bouts (Bonci & Belcher, 1994).
Significant changes in trigger point pressure threshold measures
following the use of the ROM Device have been found (Belcher, 1993).
Furthermore, the use of the ROM Device has significantly altered the
pressure threshold values of fibromyalgia patients (Masengale, 1993).
Endurance, strength and flexibility are three of the basic components of
physical fitness. During intense
exercise, all three factors are compromised by the accumulation of lactic acid.
As this by product of anaerobic metabolism accumulates in muscle tissue,
functioning is significantly compromised, contributing to fatigue. The ROM device may be employed during intense physical
activity in an attempt to rid muscles of metabolic waste and enhance energy
stores. Following activity, use of
the ROM Device for stripping massage may decrease recovery time (Bonci &
Belcher, 1994).
In general, the body contains many multi-joint muscles, ones which cross
more than one joint. Consequently,
flexibility of the entire muscle is difficult to attain.
Furthermore, uniform, in vivo stretching is difficult to assure since a
muscle is typically lengthened across one joint while it is simultaneously being
shortened across another. The ROM
Device solves this specificity dilemma. Via
employing this tool, the user can locate and treat specific tender areas in
their musculature thereby eliminating any segmentally shortened muscle (Bonci
& Belcher, 1994).
This technique provides the benefits of massage without the associated
time or cost. Specifically,
myofascial trigger points are eliminated thereby returning the muscle to its
optimal length. Via regular
application of this technique, cumulative muscle trauma may be prevented.
With respect to the time commitment for the user, the entire body can be
treated in less than 10 minutes (Belcher, 1993).
In comparison, other total body techniques take up to 45 minutes to
complete (Long, 1995).
When assessing flexibility, it is of critical importance to note that all
individuals have unique and diverse needs.
Pain and weakness may occur at any point in an individual's range of
motion. In deference to this
existence of different areas of inflexibility within a given range of motion,
there arises a need for a program which isolates tender points while
simultaneously positively affecting the entire muscle.
This ideal program is not limited to enhancing the weakest point in the
range of motion. Instead, it
accommodates the stronger regions as well, promoting a faster development of the
entire range of motion. To this
end, the ROM Device serves to meet these demands.
The Benefits of a Flexibility
Enhancement Program
Upon
assessing the benefits of a flexibility enhancement program it is key to note
that both chronic and acute adaptations exist.
Immediately following the completion of a stretching program, the
muscle's core temperature has been shown to increase.
There is an increase in the blood flow to the working muscles which
positively alters the body's blood distribution to cope with the increasing
demands placed on the musculature. Consequently,
the body's ability to deliver hemoglobin, hence oxygen, to the working muscle is
enhanced. There is also an increase
in the interactions of the muscle's actin and myosin filaments which increases
the speed and force of each muscular contraction, thereby improving performance.
A relaxation of the antagonist muscles is promoted. This reduces the resistance to movement and decreases the
risk of muscle and tendon injuries, such as strains and sprains.
As muscle tension is reduced, the body becomes more relaxed and
coordinated. This, in turn promotes
joint movement and enhances range of motion (de Swardt, 1995).
According to Mattes (1995), the implementation of a flexibility
enhancement program provides the following long term benefits.
The complete range of motion of the joint tends to be increased and
maintained. Additionally, there has
been shown to be a decrease in muscle soreness and a resulting increase in
functional activity from the employment of a flexibility enhancement program.
Furthermore, an inverse relationship has been exhibited between
neuromuscular tension and musculotendon extendibility.
Improving flexibility reduces the likelihood of strains, tears and
tightness that may result in muscular pain, spasm and cramping.
In the event of acquiring one of these ailments, range of motion
enhancement techniques play a central role in the recovery process.
Moreover, a flexibility enhancement program tends to lengthen the fascia,
which supports and stabilizes the muscles, organs and most body tissues.
The underlying tenant of a flexibility enhancement program is the
generation of a medium, which provides an ideal environment for the relaxation
of the musculature (Wood & Becker, 1981).
Time commitment to a flexibility program should be equal to one fourth of
the total training time. For instance an individual who runs 35 miles per week, with a
total training time of 245 minutes, needs to devote approximately 10 minutes per
day to flexibility enhancement. (Dellinger
& Freeman, 1984; Ebbets, 1993). These sentiments are echoed by Kokkonen and Nelson (1996) who
conclude that flexibility enhancement must be sufficient in nature as to
facilitate a full range of motion. They
continue that modalities seeking the aforementioned end may be over utilized in
the acute context when duration for an isolated bout approaches or exceeds 20
minutes. From the physiological
standpoint, this ergolytic effect may be traced to an inhibition of the spinal
cord neurons by the Golgi tendon organs following an overly aggressive acute
application of a given flexibility enhancing modality.
Time Course of Adaptation to
Training Stimuli
When examining the effect of an
ergogenic aid, with respect to the time course of a given intervention,
periodization theory forms the theoretical basis for determining the length of
the intervention. In light of the
training principle of individual response, athletes with similar
characteristics, for example: (a) training density, (b) current level of
performance, and (c) current preparedness, will generally adapt to an identical
stimulus within a reasonably similar time frame.
This adaptation is afforded by adhering to the training principle of
variation and the training program design framework of periodization.
Periodization
Overview
Periodization
refers to the different phases of training an athlete is exposed to over the
course of a competitive season. In
general, how far in advance an athlete wants to initiate preparation for
specific competition delineates the duration of each phase of training.
Each training block is rooted in the training principle of individual
response in order to meet the needs of the individual athlete.
To this end, each period seeks to addresses a specific issue as to
eliciting maximal performance (Graff, 2000).
With respect to
the process of training for athletic competition, a well organized,
scientifically based program must be implemented it order to maximize adaptation
and performance. To this end,
emphasis should be placed on rhythmical achievement (Bompa, 1989).
Via this process, performance objectives and training factors are
established at the outset of a specific training period and are used to dictate
the design of each specific training bout.
This framework, termed periodization, ensures that the athlete peaks for
the most important competitions (Bompa, 1989).
Periodization is driven by the training principles of variation and long
term training. The systematic
application of different training stimuli is necessary to facilitate optimal
physiologic functioning. Furthermore,
the sequential approach to training that is the backbone of periodization
provides the athlete with every opportunity to perfect their biomotor ability
and hone its associated metabolic demands (Bompa, 1989). In this framework training progresses from general
preparation to specific preparation and ultimately peak competition.
Periodization
divides training into distinct segments or training blocks.
This framework is comprised of three distinct divisions: (a) the
macrocycle, (b) the mesocycle, and (c) the microcycle.
The macrocycle may encompass the general training plans for an entire
year or a competitive season. The
mesocycle is a subdivision of the macrocycle that typically lasts 4 weeks.
These segments are designed address the loading of the athlete as a
function of frequency, intensity and duration of the application of training
stimuli (Bompa, 1989).
The
ultimate component in the periodization framework is the microcycle, which lasts
1-2 weeks maximum. This short
duration allows for adequate recovery between strenuous training sessions while
simultaneously achieving a balance between the steadiness of a training stimulus
and variability of the training parameters: frequency, intensity and duration.
The crux of the microcycle is to promote adaptation while avoiding
premature accommodation and staleness. It
is the most important and functional tool in training program design and
implementation since its structure and content determines the quality of the
training process (Bompa, 1989).
Time
Necessary for Adaptation
With
respect to the time necessary for the human body to initiate a response to a
given training stimulus, short term physiologic improvements in performance have
been exhibited in as little as three days (Noakes, 1986).
Moreover, at the level of the muscle tissue, alterations in function
typically begin manifestation within seven days. After three weeks of exposure,
the stimulus no longer overloads the system. Consequently, in order to maximize
adaptation, an overloading stimulus should be applied approximately every 14
days (Noakes, 1986).
Literature
Void
Upon examination of the various flexibility enhancing modalities
currently being employed in the athletic arena, it has become clear that an
eclectic technique may be used to maximize the benefits of a flexibility
enhancing program. The protocol
associated with the ROM Device serves to fill this void.
The theoretical basis of this modality is consistent with that of the
Active Isolated Stretching technique in that the muscle must be relaxed during
the stretch (Mattes, 1995). Conversely,
the static stretching modality subjects the muscle to high tension and active
contraction while attempting to improve the pliability of the muscle and its
associated connective tissues (Mattes, 1995).
An anatomical contradiction results, creating a situation where injury
may result.
Protocol associated with the use of the ROM Device borrows heavily from
massage theory. Both techniques seek to remove substances which have become
embedded in the muscle and are detrimental to performance.
Benefits include, but are not limited to, a decrease in localized
muscular pain, an enhancement in joint specific range of motion, and improved
circulation of the blood and lymphatic systems.
Additionally, these procedures allow for the isolation and removal of
specific tender points within a muscle. In
general, massage techniques have been shown to be more specific than traditional
stretches in the development of localized muscular flexibility (Bonci &
Belcher, 1994; Wood & Becker, 1981).
Treatment via the ROM Device is self
administered. This eliminates the
need for partners or professional therapists.
This call for self administered programs has been championed by Mattes
(1995) as a vital component of the Active Isolated Stretching program.
Through the elimination of an assistant who serves to facilitate
implementation of the modality, risk of injury is substantially reduced and
convenience enhanced. Furthermore, the absence of a second party eliminates
communication problems associated with conveying where trigger points are
located in the muscle.
In contrast with other flexibility enhancing modalities, certain aspects
of the ROM Device protocol are original in application.
The most prominent of these factors is the time commitment necessary for
implementation of the program. In
general, the entire body can be treated by the ROM Device in 10 minutes. This time frame contrasts favorably with those associated
with Active Isolated Stretching and massage.
In these instances, 45 to 60 minutes is necessary to effectively treat
the entire body (Bonci & Belcher, 1994; Mattes, 1995; Wood & Becker,
1981).
Another crucial aspect of flexibility physiology addressed by the ROM
Device is that of specific needs. Since
a large proportion of the body's muscles span more than one joint, traditional
flexibility enhancing modalities have difficulty in assuring that flexibility of
a specific muscle is uniform. Most
modalities incorporate a non-specific approach, in that as a muscle is shortened
across one joint, it is lengthened across another.
However, ROM Device techniques are to be implemented only on the relaxed
muscle. This allows the user to
identify and treat trigger points which result from the muscle being segmentally
shortened during exercise (Bonci & Belcher, 1994).
Despite all the theorized benefits associated with the implementation of
a flexibility enhancement program utilizing the ROM Device, there is a virtual
dearth of scientific data in which to support its claims.
This is due in part to the subjective nature of flexibility assessment,
since it is highly dependent upon subject discomfort.
Upon the implementation of a flexibility enhancement program, improved
flexibility may result. However, it
may be difficult to delineate between improvements in stretch tolerance and
actual range of motion. Another
factor hindering the scientific assessment of flexibility and its associated
improvements is the lack of a scientifically based protocol.
Notwithstanding, a lack of flexibility is most frequently exhibited in
linear activities, specifically running (Gleim & McHugh, 1997).
This may be attributed to the highly specific range of motion dictated by
activities of this nature. There is
a chronic regulation of activity specific muscle length.
Due to this constant repetition of a sub maximal range of motion, a
permanent compromise in the integrity and pliability of the musculature and its
associated structures results (Hutton, 1992).
In general, most evidence regarding the efficacy of the ROM Device is
anecdotal. Furthermore, the
generalizability of previous scientific data is limited due to characteristics
associated with the sample population. In
one instance, a convenience sample of 20 subjects, with low back pain resulting
from trigger points, was treated via the ROM Device (Belcher, 1993).
These results may be confounded due to the fact that the population was
heterogeneous in nature and the study lacked a control group. A similar study employed 12 volunteer subjects with a
clinical diagnosis of fibromyalgia (Massengale, 1993).
In this instance, the condition was not isolated in one region of the
body. Instead, this condition was
located throughout the body. Furthermore,
the subject pool was heterogeneous in nature.
Last, since all subjects were volunteers, they may have exhibited
characteristics which could differ from the population at large (Leavitt, 1991).
It is important to note that in both instances, the ROM Device was used
in an attempt to alleviate symptoms associated with various clinical maladies.
Consequently, in order to support the claims made that the ROM Device is
effective in injury prevention, flexibility enhancement and strength
improvement, a homogeneous population of athletes should be examined.
Research Hypotheses and Rationale
The ensuing hypotheses
are rooted in the aforementioned literature and derived from the research
questions.
Research
Question 1
1.
Does implementation of a self massage program utilizing the ROM Device
improve 40 meter dash performance?
Hypothesis
1. It
is hypothesized that following a 14 day intervention employing the ROM Device,
there will be a statistically significant improvement in 40 meter dash
performance.
Research
Question 2
2.
Does implementation of a self massage program utilizing the ROM Device
improve vertical jump performance?
Hypothesis
2. It
is hypothesized that following a 14 day intervention employing the ROM Device,
there will be a statistically significant improvement in vertical jump
performance.
Research
Question 3
3.
Does implementation of a self massage program utilizing the ROM Device
improve sit and reach test performance?
Hypothesis
3. It is hypothesized that following a 14 day intervention employing the
ROM Device, there will be a statistically significant improvement in sit and
reach test performance.
CHAPTER 3
METHOD
This
chapter will describe the research process of the study.
Specifically, research design, participants, test battery, intervention
procedures, statistics and issues of reliability and validity will be
delineated.
Research
Design
This study utilized two groups of 15 subjects each.
Subjects were randomly assigned to either the treatment or control group.
The experimental group received the intervention, while the control group
did not. The specifics of the time
course of the study were as follows. Each
subject was exposed to the test battery on two occasions over a 14 day span.
Pursuant to completion of the initial testing, the intervention period
commenced. During this two week phase, subjects in the treatment group
incorporated a passive flexibility enhancement program implementing the ROM
Device into their training routine. These subjects received a ROM Device
following their first exposure to the test battery and were instructed on proper
usage. They administered two
treatments per day of 50 strokes on the quadriceps, hamstrings and calves and
lumbar back. Treatments occurred
upon waking and after the daily training session, or during the evening if no
training was scheduled for the day. Members of the control group did not include any additional
flexibility enhancing modality in their training program.
At the conclusion of the 14 day intervention period, subjects were tested
for a final time.
Prior to initiating the test battery, subjects were instructed to use
their own, personal warm up routine, as employing a uniform warm up may have
interjected a confounding variable into the process.
Each participant's pre test warm up was observed and documented.
In order to minimize any skewing of the data via a training effect, a 14
day intervention period was selected. An
intervention duration of this length was sufficient as to generate a deviation
from the subject's homeostatic state (Noakes, 1986). However this two week period did not allow for complete
adaptation to the new stimulus. With
respect to the other facets of training program design and implementation,
subjects were instructed to continue training as per their current mesocycles,
with the only change being the incorporation of the ROM Device into one
microcycle. Prior to initiation of
the study, subjects completed a survey outlining their current training.
Additionally, all subjects kept a training log for the 14 day
intervention period in order to insure that no radical departure from recent
training levels occurred (Appendix A). Subjects
specified the duration and nature of workout conducted each day i.e. resistance
training, cardiovascular training, interval running.
Participants
This study utilized 30 adult males between the ages of 20 and 35 as
subjects. Subjects were residents
of the metropolitan Tallahassee, FL area. They were recruited for participation from the membership of
the Westside Athletic Club, located in Tallahassee, FL. Subjects were recreationally active, in that they viewed
their training as an end to itself, rather than a means to an end, such as
preparation for athletic competition. In
order to be considered for the subject pool, individuals must have averaged at
least 5 hours of training per week for the past six months.
Subjects were randomly assigned to the treatment and control groups.
Test Battery
With respect to assessing the effect of flexibility on athletic
performance, the following field tests were identified as both reliable and
valid: (a) sit and reach test, (b) vertical jump, (c) 40 meter dash (Coast &
Herb, 2000; Dawson, 2000; Dintiman, et al, 1997; Kipp, 2000; Mikesky, Bahamonde,
Stanton, Alvey & Fitton, 2000; Wilson, 2000).
All timing and measurements were administrated by an individual certified
in exercise testing and prescription. To
alleviate any inter-rater reliability issues, the same individual timed,
measured and recorded every trial for every subject.
The researcher was present at all testing sessions in an observational
capacity to insure that each test was conducted properly.
Within the context of each test battery exposure, each subject was given
three trials on each of the field tests. The
best score was then recorded.
Following the subject's personal warm up, tests were administered in this
order: sit and reach test, vertical jump test, 40m run.
All three trials of one test were completed before progressing to
subsequent tests. Subjects were given two minutes recovery between sit and
reach and vertical jump trials, while five minutes was given between 40 meter
run trials. Additionally, five
minutes was provided to allow subjects to move between testing stations.
Testing was conducted throughout the month of September 2000 on an
individual basis. For instance, one
subject completed the pre test battery on September 7, had an intervention
period lasting from September 8 through 22, and was tested again on September
23. Another subject had their
initial exposure to the test battery on September 11, with the subsequent 14 day
period lasting from September 12 to 26 and the post test being administered on
September 27.
Sit and Reach Test
Flexibility was measured via the
sit and reach test. This test was
chosen as the assessment for flexibility since it targeted the lower back and
hamstrings. These muscle groups are
essential contributors to lower limb force and power generation, hence athletic
performance. Based on a plethora of
relevant literature, this test is both a reliable and valid measure of hamstring
flexibility (American College of Sports Medicine, 1991; Dintiman, et al, 1997;
Kipp, 2000; Wilson, 2000).
The protocol for the sit and reach test was as follows. To insure
reliability, a steel measuring tape was used for measurement.
The tape was marked from a zero point with markings extending 60 cm fore
and 40 cm aft. The marking was done
in this way as to accommodate an individual low in flexibility, as ascertained
by this test. Subjects were
instructed to remove their shoes prior to this, and only, this test.
Then, the zero point of the tape was placed at their heels.
The subjects leaned as far forward as possible, toward their toes,
without bouncing. Once the maximal
reach was attained, the test administrator placed a thin, rigid plastic ruler
perpendicular to the measuring tape. The
intersecting point was then rounded to the nearest half centimeter and recorded.
Scores beyond the subject's heels were recorded in positive numbers,
while scores before the subject's heels were assigned negative values.
40
meter Dash Testing
The
stationary 40 meter dash was ideally suited for evaluating sprinting speed,
explosive leg power and quickness, including start and acceleration.
(Coast & Herb, 2000; Dawson, 2000; Dintiman, et al, 1997; Kipp, 2000;
Mikesky et al, 2000; Wilson, 2000). Within
the context of this test battery, the 40 meter dash was used to evaluate running
speed and to estimate power (Dintiman, et al., 1997; Kipp, 2000). This
test was conducted on a standard running track in an environment devoid of wind
assistance. Timing was done manually.
In order to eliminate subject's reaction time to an audible starting
signal, elapsed time started upon the subject's first perceivable motion and
concluded upon completion of the run (Kipp, 2000).
Vertical
Jump Testing
Lower limb power was evaluated
via the vertical jump test. In each
exposure to the testing battery, the subjects were allowed three trials, with
the highest value being recorded. The difference in height between the subject's
maximum overhead reach while standing, and the apex of their jump marked by
their outstretched hand, was used to measure vertical jump (Coast & Herb,
2000; Dawson, 2000; Dintiman, et al, 1997; Igna, Wygand & Otto, 1996; Kipp,
2000; Mikesky et al, 2000; Wilson, 2000).
Intervention Procedures
Subject usage of the ROM Device was verified as follows.
Following the first exposure to the test battery, each subject in the
treatment group received a ROM Device and was instructed on proper use.
Additionally, proper use was initially verified at this point.
On day 3 of the intervention a phone call was made to each subject to
verify proper use of the ROM Device and to address any questions or concerns
that may have arisen. On day 7 of the intervention, each subject met with the
researcher in person to verify that the ROM Device was being used properly.
A phone call with identical scope and purpose to that made on day 3 was
be made on day 11. Additionally, at
this time, arrangements were made for the subject's second exposure to the test
battery. The post test was
administered on the 14th, and final day of the intervention.
Subjects were allowed to keep the ROM Device that they used over the
course of the intervention.
Statistics
Tests and measurements are permanent ways to evaluate performance.
These techniques may be used for a variety of reasons, including but not
limited to assessing: (a) preparation for beginning a particular phase of
training, (b) the effectiveness of a completed phase of a training program, (c)
talent, and (d) the efficacy of a training modality.
Evaluation is also necessary to determine the success of a given training
program and its associated performance aims. Pursuant to this end, the data
was analyzed via paired samples t tests.
CHAPTER 4
RESULTS
The purpose of this
study was to investigate the effects associated with the employment of a self
massage program using the ROM Device on anaerobic sprint performance, and field
tests of flexibility and power.
A total of 30
recreationally active males between the ages 20 and 35 participated as subjects.
The participants were randomly assigned to either the treatment and
control groups. This study was
approved by the Human Subjects Committee of The Florida State University, and
each subject provided written consent (Appendix B).
This chapter details the data collected and associated statistics, for
this investigation.
Descriptive Data
The initial step in the investigation process was to describe the
subjects as a group, ensuring that they met the specifications with respect to
age and number of hours trained per week. As
outlined in Tables 1 and 2, the intervention and control group were similar with
respect to age and hours of training per week.
Additionally, resistance training was the predominant training modality
for all subjects.
Table 1.
Age
of Subjects in the Treatment and Control Groups